Development of a Novel Loop-Mediated Isothermal Amplification (LAMP) for Rapid Diagnosis of Newcastle Disease in Field and Resource-Limited Areas.

Uloženo v:
Podrobná bibliografie
Název: Development of a Novel Loop-Mediated Isothermal Amplification (LAMP) for Rapid Diagnosis of Newcastle Disease in Field and Resource-Limited Areas.
Autoři: Mihiretu, Berihun Dires (AUTHOR), Usui, Tatsufumi (AUTHOR), Chibssa, Tesfaye Rufael (AUTHOR), Mohammed, Abde Aliy (AUTHOR), Yamaguchi, Tsuyoshi (AUTHOR)
Zdroj: Veterinary Medicine: Research & Reports. Nov2025, Vol. 16, p39-47. 9p.
Druh dokumentu: Article
Témata: Newcastle disease, Newcastle disease virus, Diagnosis, Molecular diagnosis, Poultry, Loop-mediated isothermal amplification
Author-Supplied Keywords: loop mediated isothermal amplification
RNA preparation
Abstrakt: Background: Newcastle Disease (ND) is a highly contagious and fatal poultry disease caused by Newcastle disease virus (NDV) and has a global distribution. To control this disease, a rapid method for diagnosing it is needed. PCR-based molecular diagnostics such as real-time reverse transcription-PCR (RRT-PCR) for detecting NDV genes have been conducted worldwide. However, because PCR methods are time-consuming and require a well-equipped laboratory, they are not well-suited for use in field and resource limited areas. Methods: In this study, we established a field-friendly loop-mediated isothermal amplification (LAMP) assay for NDV diagnosis using primers targeting the highly conserved L gene, which bypasses the need for RNA extraction and makes it more suitable for field application than previously reported LAMP methods. Results: Our LAMP method is capable of detecting a broad range of NDV genotypes and showed no cross-reactivity with other avian viral diseases or the host genome. The reaction is completed within 35 minutes of incubation at 65°C. NDV was successfully detected directly from swab and tissue samples without the need for conventional RNA extraction. Conclusion: The LAMP method developed in this study offers a rapid, affordable, and field-friendly diagnostic tool for NDV detection. [ABSTRACT FROM AUTHOR]
Copyright of Veterinary Medicine: Research & Reports is the property of Dove Medical Press Ltd and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Full Text Word Count: 4246
ISSN: 2230-2034
DOI: 10.2147/VMRR.S549952
Přístupové číslo: 190276331
Databáze: Veterinary Source
Nepřihlášeným uživatelům se plný text nezobrazuje
Popis
Abstrakt:Background: Newcastle Disease (ND) is a highly contagious and fatal poultry disease caused by Newcastle disease virus (NDV) and has a global distribution. To control this disease, a rapid method for diagnosing it is needed. PCR-based molecular diagnostics such as real-time reverse transcription-PCR (RRT-PCR) for detecting NDV genes have been conducted worldwide. However, because PCR methods are time-consuming and require a well-equipped laboratory, they are not well-suited for use in field and resource limited areas. Methods: In this study, we established a field-friendly loop-mediated isothermal amplification (LAMP) assay for NDV diagnosis using primers targeting the highly conserved L gene, which bypasses the need for RNA extraction and makes it more suitable for field application than previously reported LAMP methods. Results: Our LAMP method is capable of detecting a broad range of NDV genotypes and showed no cross-reactivity with other avian viral diseases or the host genome. The reaction is completed within 35 minutes of incubation at 65°C. NDV was successfully detected directly from swab and tissue samples without the need for conventional RNA extraction. Conclusion: The LAMP method developed in this study offers a rapid, affordable, and field-friendly diagnostic tool for NDV detection. [ABSTRACT FROM AUTHOR]
ISSN:22302034
DOI:10.2147/VMRR.S549952