Objective verification of audibility in bone conduction devices
Uložené v:
| Názov: | Objective verification of audibility in bone conduction devices |
|---|---|
| Autori: | Persson, Ann -Charlotte, Håkansson, Bo, 1953, Fredén Jansson, Karl-Johan, 1988, Reinfeldt, Sabine, 1978, Eeg-Olofsson, Mans |
| Zdroj: | International Journal of Audiology. 64(3):217-223 |
| Predmety: | skin microphone, objective verification, audibility, hearing rehabilitation, Bone conduction devices |
| Popis: | ObjectiveTo objectively measure audibility in patients wearing bone conduction devices (BCDs) with a new approach using a skin microphone at the patient's forehead.DesignThe skin microphone was attached by a softband and shielded by an earmuff. This set-up was confirmed not to be influenced by neither noise floor nor sound bypassing the BCD. Sound field warble tones were used for measuring aided hearing thresholds and maximum power output (MPO) whereas an international speech test signal (ISTS) was presented at different speech levels.Study sample29 patients were tested (two were bilateral), 19 used percutaneous, eight used active transcutaneous and two used passive transcutaneous devices.ResultsThe skin microphone responses at ISTS levels, hearing threshold and MPO, could be obtained in all patients. Two patients with poor audibility are highlighted in this article as examples. After adjusting the gain of the BCD, they were retested with the skin microphone (for verification) and with speech-in-noise tests (for validation). Both tests confirmed an improved audibility after the adjustments.ConclusionIn summary, the proposed measurement of audibility of speech using a skin microphone is a promising method that can be used in a clinical setting for all types of BCDs. |
| Popis súboru: | electronic |
| Prístupová URL adresa: | https://research.chalmers.se/publication/540748 https://research.chalmers.se/publication/540748/file/540748_Fulltext.pdf |
| Databáza: | SwePub |
| FullText | Text: Availability: 0 CustomLinks: – Url: https://research.chalmers.se/publication/540748# Name: EDS - SwePub (s4221598) Category: fullText Text: View record in SwePub – Url: https://resolver.ebscohost.com/openurl?sid=EBSCO:edsswe&genre=article&issn=14992027&ISBN=&volume=64&issue=3&date=20250101&spage=217&pages=217-223&title=International Journal of Audiology&atitle=Objective%20verification%20of%20audibility%20in%20bone%20conduction%20devices&aulast=Persson%2C%20Ann%20-Charlotte&id=DOI:10.1080/14992027.2024.2335511 Name: Full Text Finder Category: fullText Text: Full Text Finder Icon: https://imageserver.ebscohost.com/branding/images/FTF.gif MouseOverText: Full Text Finder – Url: https://www.webofscience.com/api/gateway?GWVersion=2&SrcApp=EBSCO&SrcAuth=EBSCO&DestApp=WOS&ServiceName=TransferToWoS&DestLinkType=GeneralSearchSummary&Func=Links&author=Persson%20AC Name: ISI Category: fullText Text: Nájsť tento článok vo Web of Science Icon: https://imagesrvr.epnet.com/ls/20docs.gif MouseOverText: Nájsť tento článok vo Web of Science |
|---|---|
| Header | DbId: edsswe DbLabel: SwePub An: edsswe.oai.research.chalmers.se.641eac28.ed91.4080.b4a6.a13acaab4ba8 RelevancyScore: 1115 AccessLevel: 6 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 1114.736328125 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: Objective verification of audibility in bone conduction devices – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AR" term="%22Persson%2C+Ann+-Charlotte%22">Persson, Ann -Charlotte</searchLink><br /><searchLink fieldCode="AR" term="%22Håkansson%2C+Bo%22">Håkansson, Bo</searchLink>, 1953<br /><searchLink fieldCode="AR" term="%22Fredén+Jansson%2C+Karl-Johan%22">Fredén Jansson, Karl-Johan</searchLink>, 1988<br /><searchLink fieldCode="AR" term="%22Reinfeldt%2C+Sabine%22">Reinfeldt, Sabine</searchLink>, 1978<br /><searchLink fieldCode="AR" term="%22Eeg-Olofsson%2C+Mans%22">Eeg-Olofsson, Mans</searchLink> – Name: TitleSource Label: Source Group: Src Data: <i>International Journal of Audiology</i>. 64(3):217-223 – Name: Subject Label: Subject Terms Group: Su Data: <searchLink fieldCode="DE" term="%22skin+microphone%22">skin microphone</searchLink><br /><searchLink fieldCode="DE" term="%22objective+verification%22">objective verification</searchLink><br /><searchLink fieldCode="DE" term="%22audibility%22">audibility</searchLink><br /><searchLink fieldCode="DE" term="%22hearing+rehabilitation%22">hearing rehabilitation</searchLink><br /><searchLink fieldCode="DE" term="%22Bone+conduction+devices%22">Bone conduction devices</searchLink> – Name: Abstract Label: Description Group: Ab Data: ObjectiveTo objectively measure audibility in patients wearing bone conduction devices (BCDs) with a new approach using a skin microphone at the patient's forehead.DesignThe skin microphone was attached by a softband and shielded by an earmuff. This set-up was confirmed not to be influenced by neither noise floor nor sound bypassing the BCD. Sound field warble tones were used for measuring aided hearing thresholds and maximum power output (MPO) whereas an international speech test signal (ISTS) was presented at different speech levels.Study sample29 patients were tested (two were bilateral), 19 used percutaneous, eight used active transcutaneous and two used passive transcutaneous devices.ResultsThe skin microphone responses at ISTS levels, hearing threshold and MPO, could be obtained in all patients. Two patients with poor audibility are highlighted in this article as examples. After adjusting the gain of the BCD, they were retested with the skin microphone (for verification) and with speech-in-noise tests (for validation). Both tests confirmed an improved audibility after the adjustments.ConclusionIn summary, the proposed measurement of audibility of speech using a skin microphone is a promising method that can be used in a clinical setting for all types of BCDs. – Name: Format Label: File Description Group: SrcInfo Data: electronic – Name: URL Label: Access URL Group: URL Data: <link linkTarget="URL" linkTerm="https://research.chalmers.se/publication/540748" linkWindow="_blank">https://research.chalmers.se/publication/540748</link><br /><link linkTarget="URL" linkTerm="https://research.chalmers.se/publication/540748/file/540748_Fulltext.pdf" linkWindow="_blank">https://research.chalmers.se/publication/540748/file/540748_Fulltext.pdf</link> |
| PLink | https://erproxy.cvtisr.sk/sfx/access?url=https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=edsswe&AN=edsswe.oai.research.chalmers.se.641eac28.ed91.4080.b4a6.a13acaab4ba8 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.1080/14992027.2024.2335511 Languages: – Text: English PhysicalDescription: Pagination: PageCount: 7 StartPage: 217 Subjects: – SubjectFull: skin microphone Type: general – SubjectFull: objective verification Type: general – SubjectFull: audibility Type: general – SubjectFull: hearing rehabilitation Type: general – SubjectFull: Bone conduction devices Type: general Titles: – TitleFull: Objective verification of audibility in bone conduction devices Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Persson, Ann -Charlotte – PersonEntity: Name: NameFull: Håkansson, Bo – PersonEntity: Name: NameFull: Fredén Jansson, Karl-Johan – PersonEntity: Name: NameFull: Reinfeldt, Sabine – PersonEntity: Name: NameFull: Eeg-Olofsson, Mans IsPartOfRelationships: – BibEntity: Dates: – D: 01 M: 01 Type: published Y: 2025 Identifiers: – Type: issn-print Value: 14992027 – Type: issn-print Value: 17088186 – Type: issn-locals Value: SWEPUB_FREE – Type: issn-locals Value: CTH_SWEPUB Numbering: – Type: volume Value: 64 – Type: issue Value: 3 Titles: – TitleFull: International Journal of Audiology Type: main |
| ResultId | 1 |
Full Text Finder
Nájsť tento článok vo Web of Science