Reliability and Accuracy of Standard Reference Procedures for Measurements of Trunk and Arm Postures in Ergonomics
Uloženo v:
| Název: | Reliability and Accuracy of Standard Reference Procedures for Measurements of Trunk and Arm Postures in Ergonomics |
|---|---|
| Autoři: | Lind, Carl Mikael, Rhen, Ida-Märta, 1975, Forsman, Mikael, 1963 |
| Zdroj: | Bioengineering. 12(1) |
| Témata: | measurement error, posture assessment, measurement bias, plumb line test, normal standing position, inclinometry, standard posture, work postures, wearables, calibration procedures |
| Popis: | Adequate reference procedures for obtaining the reference zero-angle position are important for precise and accurate posture measurements, but few studies have systematically investigated these. A limited number of previous studies suggest differences in accuracy between procedures, with some causing an underestimation of the true arm elevation angle when sensors are taped to the skin. The reliability of commonly used reference procedures for the measurement of the trunk posture is also not well explored, and alternative procedures may improve precision. Based on this identified gap, this study evaluated the test–retest reliability of the N-position (I-pose), i.e., the standard procedure for recording trunk postures, and compared it with two new alternative procedures. Additionally, the accuracy of the N-position for measuring arm elevation angles was compared with one alternative procedure. A total of 40 participants (22 women and 18 men) aged 26–70 years performed the reference procedures in a laboratory setting. Postures were recorded using a smart workwear system equipped with two inertial measurement units (IMUs) embedded in pockets within the workwear. For the trunk posture, the N-position showed a slight lack of test–retest reliability, while one of the alternative procedures demonstrated better test–retest reliability. For the arm posture, the N-position, which does not include lateral trunk inclination, resulted in a substantial underestimation of the arm elevation angle of approximately 15°, which is a novel finding. In contrast, the posture involving trunk inclination closely matched the targeted reference, with a difference of less than 2°. This study underscores the importance of selecting appropriate reference procedures to ensure precise and accurate posture measurements. |
| Popis souboru: | electronic |
| Přístupová URL adresa: | https://research.chalmers.se/publication/544952 https://research.chalmers.se/publication/544952/file/544952_Fulltext.pdf |
| Databáze: | SwePub |
| FullText | Text: Availability: 0 CustomLinks: – Url: https://research.chalmers.se/publication/544952# Name: EDS - SwePub (s4221598) Category: fullText Text: View record in SwePub – Url: http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?cmd=search&db=pmc&term=2306-5354[TA]+AND+[PG]+AND+2025[PDAT] Name: FREE - PubMed Central (ISSN based link) Category: fullText Text: Full Text Icon: https://imageserver.ebscohost.com/NetImages/iconPdf.gif MouseOverText: Check this PubMed for the article full text. – Url: https://resolver.ebscohost.com/openurl?sid=EBSCO:edsswe&genre=article&issn=23065354&ISBN=&volume=12&issue=1&date=20250101&spage=&pages=&title=Bioengineering&atitle=Reliability%20and%20Accuracy%20of%20Standard%20Reference%20Procedures%20for%20Measurements%20of%20Trunk%20and%20Arm%20Postures%20in%20Ergonomics&aulast=Lind%2C%20Carl%20Mikael&id=DOI:10.3390/bioengineering12010050 Name: Full Text Finder Category: fullText Text: Full Text Finder Icon: https://imageserver.ebscohost.com/branding/images/FTF.gif MouseOverText: Full Text Finder – Url: https://www.webofscience.com/api/gateway?GWVersion=2&SrcApp=EBSCO&SrcAuth=EBSCO&DestApp=WOS&ServiceName=TransferToWoS&DestLinkType=GeneralSearchSummary&Func=Links&author=Lind%20CM Name: ISI Category: fullText Text: Nájsť tento článok vo Web of Science Icon: https://imagesrvr.epnet.com/ls/20docs.gif MouseOverText: Nájsť tento článok vo Web of Science |
|---|---|
| Header | DbId: edsswe DbLabel: SwePub An: edsswe.oai.research.chalmers.se.1a7d70b4.0d94.4870.8a2e.e867e4d46b9b RelevancyScore: 1065 AccessLevel: 6 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 1064.736328125 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: Reliability and Accuracy of Standard Reference Procedures for Measurements of Trunk and Arm Postures in Ergonomics – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AR" term="%22Lind%2C+Carl+Mikael%22">Lind, Carl Mikael</searchLink><br /><searchLink fieldCode="AR" term="%22Rhen%2C+Ida-Märta%22">Rhen, Ida-Märta</searchLink>, 1975<br /><searchLink fieldCode="AR" term="%22Forsman%2C+Mikael%22">Forsman, Mikael</searchLink>, 1963 – Name: TitleSource Label: Source Group: Src Data: <i>Bioengineering</i>. 12(1) – Name: Subject Label: Subject Terms Group: Su Data: <searchLink fieldCode="DE" term="%22measurement+error%22">measurement error</searchLink><br /><searchLink fieldCode="DE" term="%22posture+assessment%22">posture assessment</searchLink><br /><searchLink fieldCode="DE" term="%22measurement+bias%22">measurement bias</searchLink><br /><searchLink fieldCode="DE" term="%22plumb+line+test%22">plumb line test</searchLink><br /><searchLink fieldCode="DE" term="%22normal+standing+position%22">normal standing position</searchLink><br /><searchLink fieldCode="DE" term="%22inclinometry%22">inclinometry</searchLink><br /><searchLink fieldCode="DE" term="%22standard+posture%22">standard posture</searchLink><br /><searchLink fieldCode="DE" term="%22work+postures%22">work postures</searchLink><br /><searchLink fieldCode="DE" term="%22wearables%22">wearables</searchLink><br /><searchLink fieldCode="DE" term="%22calibration+procedures%22">calibration procedures</searchLink> – Name: Abstract Label: Description Group: Ab Data: Adequate reference procedures for obtaining the reference zero-angle position are important for precise and accurate posture measurements, but few studies have systematically investigated these. A limited number of previous studies suggest differences in accuracy between procedures, with some causing an underestimation of the true arm elevation angle when sensors are taped to the skin. The reliability of commonly used reference procedures for the measurement of the trunk posture is also not well explored, and alternative procedures may improve precision. Based on this identified gap, this study evaluated the test–retest reliability of the N-position (I-pose), i.e., the standard procedure for recording trunk postures, and compared it with two new alternative procedures. Additionally, the accuracy of the N-position for measuring arm elevation angles was compared with one alternative procedure. A total of 40 participants (22 women and 18 men) aged 26–70 years performed the reference procedures in a laboratory setting. Postures were recorded using a smart workwear system equipped with two inertial measurement units (IMUs) embedded in pockets within the workwear. For the trunk posture, the N-position showed a slight lack of test–retest reliability, while one of the alternative procedures demonstrated better test–retest reliability. For the arm posture, the N-position, which does not include lateral trunk inclination, resulted in a substantial underestimation of the arm elevation angle of approximately 15°, which is a novel finding. In contrast, the posture involving trunk inclination closely matched the targeted reference, with a difference of less than 2°. This study underscores the importance of selecting appropriate reference procedures to ensure precise and accurate posture measurements. – Name: Format Label: File Description Group: SrcInfo Data: electronic – Name: URL Label: Access URL Group: URL Data: <link linkTarget="URL" linkTerm="https://research.chalmers.se/publication/544952" linkWindow="_blank">https://research.chalmers.se/publication/544952</link><br /><link linkTarget="URL" linkTerm="https://research.chalmers.se/publication/544952/file/544952_Fulltext.pdf" linkWindow="_blank">https://research.chalmers.se/publication/544952/file/544952_Fulltext.pdf</link> |
| PLink | https://erproxy.cvtisr.sk/sfx/access?url=https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=edsswe&AN=edsswe.oai.research.chalmers.se.1a7d70b4.0d94.4870.8a2e.e867e4d46b9b |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.3390/bioengineering12010050 Languages: – Text: English Subjects: – SubjectFull: measurement error Type: general – SubjectFull: posture assessment Type: general – SubjectFull: measurement bias Type: general – SubjectFull: plumb line test Type: general – SubjectFull: normal standing position Type: general – SubjectFull: inclinometry Type: general – SubjectFull: standard posture Type: general – SubjectFull: work postures Type: general – SubjectFull: wearables Type: general – SubjectFull: calibration procedures Type: general Titles: – TitleFull: Reliability and Accuracy of Standard Reference Procedures for Measurements of Trunk and Arm Postures in Ergonomics Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Lind, Carl Mikael – PersonEntity: Name: NameFull: Rhen, Ida-Märta – PersonEntity: Name: NameFull: Forsman, Mikael IsPartOfRelationships: – BibEntity: Dates: – D: 01 M: 01 Type: published Y: 2025 Identifiers: – Type: issn-print Value: 23065354 – Type: issn-locals Value: SWEPUB_FREE – Type: issn-locals Value: CTH_SWEPUB Numbering: – Type: volume Value: 12 – Type: issue Value: 1 Titles: – TitleFull: Bioengineering Type: main |
| ResultId | 1 |