Controladores robustos adaptativos para um conversor trifásico a três fios conectado à rede com filtro LCL ; Robust adaptive controllers for a three-phase grid-tied 3-wire converter by LCL filter

Gespeichert in:
Bibliographische Detailangaben
Titel: Controladores robustos adaptativos para um conversor trifásico a três fios conectado à rede com filtro LCL ; Robust adaptive controllers for a three-phase grid-tied 3-wire converter by LCL filter
Autoren: Evald, Paulo Jefferson Dias de Oliveira
Weitere Verfasser: Grundling, Hilton Abílio, http://lattes.cnpq.br/6128096609162437, Stefanello, Marcio, Lima, Sigmar de, Gastaldini, Cristiane Cauduro, Vieira, Rodrigo Padilha
Verlagsinformationen: Universidade Federal de Santa Maria
Brasil
Engenharia Elétrica
UFSM
Programa de Pós-Graduação em Engenharia Elétrica
Centro de Tecnologia
Publikationsjahr: 2021
Bestand: Manancial - Repositório Digital da UFSM (Universidade Federal de Santa Maria)
Schlagwörter: Controlador robusto adaptativo, Controlador discreto no tempo, Filtro LCL, Modelo de ordem reduzida, Conversores conectados à rede elétrica, Robust adaptive controller, Discrete-time controller, LCL filter, Reduced order model, Grid-tied converters, CNPQ::ENGENHARIAS::ENGENHARIA ELETRICA
Beschreibung: This work presents new robust adaptive control strategies of adaptive robust controllers, in discrete time, applied to the grid-injected currents control of a voltage-fed three-phase three-wires static converter connected to the electrical grid with LCL filter. The application of adaptive controllers on grid-tied converters is justified due to the uncertainties and pa- rametric variations inherent to the grid impedance. However, typically, adaptive controllers based on a reference model implemented for this application are complexes, because the reference model need to has the same relative degree of modelled part of the plant, which is equal to three, in continuous time, or relative degree equal to two, if discretised consi- dering implementation delay. It implies on a complex control design and will require a high processing capacity from microcontroller to execute it. Thereby, initially an order reduction of LCL filter model is proposed, where is demonstrated mathematically that filter capacitor can be considered as an unmodelled dynamics of additive type, resulting in an first order model. With this, it is possible to design a robust adaptive controller with a first order re- ference model, since the relative degree of the modelled part of the plant is one. Next, two new robust adaptive controllers are proposed, entirely in discrete time. The first new strategy, PI-RMRAC, is a robust PI (Proportional-Integral) controller based on a reference model. This new control approach is a reformulation of the parameter vector, which, like the previous strategy, is based on a first-order reference model. The second proposed new controller, a robust adaptive PI controller, tracks straightforwardly the reference currents, consequently it does not require the reference model implementation, further simplifying the controller design. In this controller, the identification of adaptive gains is equivalent to estimate, indirectly, the closed-loop system gains. Furthermore, the stability and robustness proofs of controllers, in ...
Publikationsart: thesis
Dateibeschreibung: application/pdf
Sprache: Portuguese
Relation: http://repositorio.ufsm.br/handle/1/22697
Verfügbarkeit: http://repositorio.ufsm.br/handle/1/22697
Rights: Attribution-NonCommercial-NoDerivatives 4.0 International ; http://creativecommons.org/licenses/by-nc-nd/4.0/
Dokumentencode: edsbas.BDC98BA2
Datenbank: BASE
Beschreibung
Abstract:This work presents new robust adaptive control strategies of adaptive robust controllers, in discrete time, applied to the grid-injected currents control of a voltage-fed three-phase three-wires static converter connected to the electrical grid with LCL filter. The application of adaptive controllers on grid-tied converters is justified due to the uncertainties and pa- rametric variations inherent to the grid impedance. However, typically, adaptive controllers based on a reference model implemented for this application are complexes, because the reference model need to has the same relative degree of modelled part of the plant, which is equal to three, in continuous time, or relative degree equal to two, if discretised consi- dering implementation delay. It implies on a complex control design and will require a high processing capacity from microcontroller to execute it. Thereby, initially an order reduction of LCL filter model is proposed, where is demonstrated mathematically that filter capacitor can be considered as an unmodelled dynamics of additive type, resulting in an first order model. With this, it is possible to design a robust adaptive controller with a first order re- ference model, since the relative degree of the modelled part of the plant is one. Next, two new robust adaptive controllers are proposed, entirely in discrete time. The first new strategy, PI-RMRAC, is a robust PI (Proportional-Integral) controller based on a reference model. This new control approach is a reformulation of the parameter vector, which, like the previous strategy, is based on a first-order reference model. The second proposed new controller, a robust adaptive PI controller, tracks straightforwardly the reference currents, consequently it does not require the reference model implementation, further simplifying the controller design. In this controller, the identification of adaptive gains is equivalent to estimate, indirectly, the closed-loop system gains. Furthermore, the stability and robustness proofs of controllers, in ...