Multivariable Control-Based dq Decoupling in Voltage and Current Control Loops for Enhanced Transient Response and Power Delivery in Microgrids
Saved in:
| Title: | Multivariable Control-Based dq Decoupling in Voltage and Current Control Loops for Enhanced Transient Response and Power Delivery in Microgrids |
|---|---|
| Authors: | Mandarapu Srikanth, Yellapragada Venkata Pavan Kumar, Challa Pradeep Reddy, Rammohan Mallipeddi |
| Source: | Energies, Vol 17, Iss 15, p 3689 (2024) |
| Publisher Information: | MDPI AG |
| Publication Year: | 2024 |
| Collection: | Directory of Open Access Journals: DOAJ Articles |
| Subject Terms: | dq decoupling, pole-zero cancellation, power delivery, microgrids, multiloop control, multivariable control, Technology |
| Description: | Being multivariable in nature, voltage and current control loops have controllers in the forward and cross-coupling paths. Most methods discussed in the literature focus on tuning the controllers in the forward paths to reduce the dq coupling. A modified pole-zero cancellation (MPZC) technique has recently been discussed, which uses the concepts of pole-zero cancellation and particle swarm optimization to effectively tune the forward path controllers. However, given the fixed gains in the cross-coupling paths, it is not possible to realize a superior transient response from this technique. Therefore, to achieve enhanced vector control of VSIs under transient conditions, this paper proposes a hybrid MPZC (HMPZC) method, which incorporates multivariable control along with the MPZC technique for both voltage/current control loops. In the proposed HMPZC method, the MPZC method is used to tune the forward path controllers, and multivariable control-based PI controllers are assigned in the cross-coupling paths of dq-axes loops rather than fixed gains. In this paper, these multivariable control-based PI controllers are designed using direct synthesis method-based internal model control (IMC). From the simulation results, it is verified that the proposed HMPZC method has reduced the coupling between the d- and q-axes loops of the current/voltage, leading to the improved transient response and power delivery capability of VSIs. |
| Document Type: | article in journal/newspaper |
| Language: | English |
| Relation: | https://www.mdpi.com/1996-1073/17/15/3689; https://doaj.org/toc/1996-1073; https://doaj.org/article/053cfd23d993434e9acc8b0b776fa934 |
| DOI: | 10.3390/en17153689 |
| Availability: | https://doi.org/10.3390/en17153689 https://doaj.org/article/053cfd23d993434e9acc8b0b776fa934 |
| Accession Number: | edsbas.6B91073A |
| Database: | BASE |
| Abstract: | Being multivariable in nature, voltage and current control loops have controllers in the forward and cross-coupling paths. Most methods discussed in the literature focus on tuning the controllers in the forward paths to reduce the dq coupling. A modified pole-zero cancellation (MPZC) technique has recently been discussed, which uses the concepts of pole-zero cancellation and particle swarm optimization to effectively tune the forward path controllers. However, given the fixed gains in the cross-coupling paths, it is not possible to realize a superior transient response from this technique. Therefore, to achieve enhanced vector control of VSIs under transient conditions, this paper proposes a hybrid MPZC (HMPZC) method, which incorporates multivariable control along with the MPZC technique for both voltage/current control loops. In the proposed HMPZC method, the MPZC method is used to tune the forward path controllers, and multivariable control-based PI controllers are assigned in the cross-coupling paths of dq-axes loops rather than fixed gains. In this paper, these multivariable control-based PI controllers are designed using direct synthesis method-based internal model control (IMC). From the simulation results, it is verified that the proposed HMPZC method has reduced the coupling between the d- and q-axes loops of the current/voltage, leading to the improved transient response and power delivery capability of VSIs. |
|---|---|
| DOI: | 10.3390/en17153689 |