Half-life Measurement of Fission Product 90Rb
Uloženo v:
| Název: | Half-life Measurement of Fission Product 90Rb |
|---|---|
| Zdroj: | Yuanzineng kexue jishu, Vol 57, Iss 8, Pp 1498-1503 (2023) |
| Informace o vydavateli: | Editorial Board of Atomic Energy Science and Technology |
| Rok vydání: | 2023 |
| Sbírka: | Directory of Open Access Journals: DOAJ Articles |
| Témata: | 90rb, half-life, reference source, Nuclear engineering. Atomic power, TK9001-9401, Nuclear and particle physics. Atomic energy. Radioactivity, QC770-798 |
| Popis: | 90Rb is a high-yield short-lived fission product, a highly sensitive detector for low fission burnup, and its half-life is an important nuclear parameter. At present, the ENSDF (Evaluated Nuclear Structure Data File) evaluated value for the half-life of 90Rb is (158±5) s (±3.2%). Due to the low energy resolution of early detectors such as Geiger counter, proportional counter and Ge(Li) detector and significant interference of impurity nuclides during the measurement process, the evaluated value is resulted in a high degree of uncertainty, which can’t meet the requirements of low fission burnup analysis. Therefore, it is of practical application value to determine the half-life of 90Rb. In this work, the half-life of 90Rb was tracked and measured by the reference source method with a better energy resolution coaxial HPGe γ spectrometer. During the measurement, characteristic γ radiations of 60Co reference source (1 173.23 keV and 1 332.50 keV) and 90Rb determine source (3 534.24, 4 135.51 and 4 365.9 keV) were tracked. In order to avoid the influence of counting correction caused by dead time and pulse pile-up during the measurement, the ratio R between the counting of 90Rb γ radiations (3 534.24, 4 135.51 and 4 365.9 keV) and the counting of the two characteristic energy (1 173.23 keV and 1 332.50 keV) of 60Co was calculated. By means of weighted linear fitting method, the slope of the ln R-t fitting curve was obtained, and the experimental values of 90Rb half-life were calculated. The uncertainty of the experimental values was comprehensively considered, taking into account the uncertainty introduced by linear fitting and statistical counting. Finally, the weighted average of the experimental values was calculated and the final half-life value with a combined uncertainty was obtained as (160.50±0.47) s (±0.29%). In order to test the reliability of the final half-life value, the relative uncertainty of the data points in each fitting curve was obtained by amplifying the difference between the data points in each ... |
| Druh dokumentu: | article in journal/newspaper |
| Jazyk: | English Chinese |
| Relation: | https://www.aest.org.cn/CN/10.7538/yzk.2023.youxian.0235; https://doaj.org/toc/1000-6931; https://doaj.org/article/a6e63589da294db3922077a0dfff3b86 |
| Dostupnost: | https://doaj.org/article/a6e63589da294db3922077a0dfff3b86 |
| Přístupové číslo: | edsbas.4303DCF7 |
| Databáze: | BASE |
| FullText | Text: Availability: 0 CustomLinks: – Url: https://doaj.org/article/a6e63589da294db3922077a0dfff3b86# Name: EDS - BASE (s4221598) Category: fullText Text: View record from BASE – Url: https://www.webofscience.com/api/gateway?GWVersion=2&SrcApp=EBSCO&SrcAuth=EBSCO&DestApp=WOS&ServiceName=TransferToWoS&DestLinkType=GeneralSearchSummary&Func=Links&author= Name: ISI Category: fullText Text: Nájsť tento článok vo Web of Science Icon: https://imagesrvr.epnet.com/ls/20docs.gif MouseOverText: Nájsť tento článok vo Web of Science |
|---|---|
| Header | DbId: edsbas DbLabel: BASE An: edsbas.4303DCF7 RelevancyScore: 944 AccessLevel: 3 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 943.653564453125 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: Half-life Measurement of Fission Product 90Rb – Name: TitleSource Label: Source Group: Src Data: Yuanzineng kexue jishu, Vol 57, Iss 8, Pp 1498-1503 (2023) – Name: Publisher Label: Publisher Information Group: PubInfo Data: Editorial Board of Atomic Energy Science and Technology – Name: DatePubCY Label: Publication Year Group: Date Data: 2023 – Name: Subset Label: Collection Group: HoldingsInfo Data: Directory of Open Access Journals: DOAJ Articles – Name: Subject Label: Subject Terms Group: Su Data: <searchLink fieldCode="DE" term="%2290rb%22">90rb</searchLink><br /><searchLink fieldCode="DE" term="%22half-life%22">half-life</searchLink><br /><searchLink fieldCode="DE" term="%22reference+source%22">reference source</searchLink><br /><searchLink fieldCode="DE" term="%22Nuclear+engineering%2E+Atomic+power%22">Nuclear engineering. Atomic power</searchLink><br /><searchLink fieldCode="DE" term="%22TK9001-9401%22">TK9001-9401</searchLink><br /><searchLink fieldCode="DE" term="%22Nuclear+and+particle+physics%2E+Atomic+energy%2E+Radioactivity%22">Nuclear and particle physics. Atomic energy. Radioactivity</searchLink><br /><searchLink fieldCode="DE" term="%22QC770-798%22">QC770-798</searchLink> – Name: Abstract Label: Description Group: Ab Data: 90Rb is a high-yield short-lived fission product, a highly sensitive detector for low fission burnup, and its half-life is an important nuclear parameter. At present, the ENSDF (Evaluated Nuclear Structure Data File) evaluated value for the half-life of 90Rb is (158±5) s (±3.2%). Due to the low energy resolution of early detectors such as Geiger counter, proportional counter and Ge(Li) detector and significant interference of impurity nuclides during the measurement process, the evaluated value is resulted in a high degree of uncertainty, which can’t meet the requirements of low fission burnup analysis. Therefore, it is of practical application value to determine the half-life of 90Rb. In this work, the half-life of 90Rb was tracked and measured by the reference source method with a better energy resolution coaxial HPGe γ spectrometer. During the measurement, characteristic γ radiations of 60Co reference source (1 173.23 keV and 1 332.50 keV) and 90Rb determine source (3 534.24, 4 135.51 and 4 365.9 keV) were tracked. In order to avoid the influence of counting correction caused by dead time and pulse pile-up during the measurement, the ratio R between the counting of 90Rb γ radiations (3 534.24, 4 135.51 and 4 365.9 keV) and the counting of the two characteristic energy (1 173.23 keV and 1 332.50 keV) of 60Co was calculated. By means of weighted linear fitting method, the slope of the ln R-t fitting curve was obtained, and the experimental values of 90Rb half-life were calculated. The uncertainty of the experimental values was comprehensively considered, taking into account the uncertainty introduced by linear fitting and statistical counting. Finally, the weighted average of the experimental values was calculated and the final half-life value with a combined uncertainty was obtained as (160.50±0.47) s (±0.29%). In order to test the reliability of the final half-life value, the relative uncertainty of the data points in each fitting curve was obtained by amplifying the difference between the data points in each ... – Name: TypeDocument Label: Document Type Group: TypDoc Data: article in journal/newspaper – Name: Language Label: Language Group: Lang Data: English<br />Chinese – Name: NoteTitleSource Label: Relation Group: SrcInfo Data: https://www.aest.org.cn/CN/10.7538/yzk.2023.youxian.0235; https://doaj.org/toc/1000-6931; https://doaj.org/article/a6e63589da294db3922077a0dfff3b86 – Name: URL Label: Availability Group: URL Data: https://doaj.org/article/a6e63589da294db3922077a0dfff3b86 – Name: AN Label: Accession Number Group: ID Data: edsbas.4303DCF7 |
| PLink | https://erproxy.cvtisr.sk/sfx/access?url=https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=edsbas&AN=edsbas.4303DCF7 |
| RecordInfo | BibRecord: BibEntity: Languages: – Text: English – Text: Chinese Subjects: – SubjectFull: 90rb Type: general – SubjectFull: half-life Type: general – SubjectFull: reference source Type: general – SubjectFull: Nuclear engineering. Atomic power Type: general – SubjectFull: TK9001-9401 Type: general – SubjectFull: Nuclear and particle physics. Atomic energy. Radioactivity Type: general – SubjectFull: QC770-798 Type: general Titles: – TitleFull: Half-life Measurement of Fission Product 90Rb Type: main BibRelationships: IsPartOfRelationships: – BibEntity: Dates: – D: 01 M: 01 Type: published Y: 2023 Identifiers: – Type: issn-locals Value: edsbas – Type: issn-locals Value: edsbas.oa Titles: – TitleFull: Yuanzineng kexue jishu Type: main |
| ResultId | 1 |
Nájsť tento článok vo Web of Science