Press-Fit Placement of a Rectangular Block Implant in the Resorbed Alveolar Ridge: Surgical and Biomechanical Considerations
Saved in:
| Title: | Press-Fit Placement of a Rectangular Block Implant in the Resorbed Alveolar Ridge: Surgical and Biomechanical Considerations |
|---|---|
| Authors: | Efthimios Gazelakis, Roy B. Judge, Joseph E. A. Palamara, Shiva Subramanian, Mohsin Nazir |
| Source: | Bioengineering, Vol 11, Iss 6, p 532 (2024) |
| Publisher Information: | MDPI AG |
| Publication Year: | 2024 |
| Collection: | Directory of Open Access Journals: DOAJ Articles |
| Subject Terms: | rectangular block implant, rectangular osteotomy, primary retention, placement load, osseo-integration, stress concentration, Technology, Biology (General), QH301-705.5 |
| Description: | Rectangular Block Implant (RBIs) were manufactured, using computer-aided-design lathe turning, surface roughened with grit blasting and gamma irradiated. Implants were surgically placed into the resorbed edentulous mandibular ridges of both greyhound dogs (ex vivo and in vivo) and humans; the pooled total was 17 placements. The aim was to achieve mechanical stability and full implant submergence without damage to the mandibular canal and without bone fracture: fulfilment of all of these criteria was deemed to be a successful surgical outcome. Rectangular osteotomy sites were prepared with piezo surgical instrumentation. Sixteen implants were fully submerged and achieved good primary stability without bone fracture and without evidence of impingement of the mandibular canal. One implant placement was deemed a failure due to bone fracture: the event of a random successful outcome was rejected ( p < 0.01 confidence, binomial analysis). Technique of placement yielded excellent mechanical retention: key biomechanical factors that emerged in this process included under preparation of the osteotomy site with the use of specifically designed trial-fit gauges, the viscoelastic property of the peri-implant bone, the flat faces and cornered edges of the block surfaces which enhance stress distribution and mechanical retention, respectively. It was concluded that the surgical protocol for the RBI placement in the resorbed alveolus is a predictable clinical procedure tailored to its specific, unique biomechanical profile. |
| Document Type: | article in journal/newspaper |
| Language: | English |
| Relation: | https://www.mdpi.com/2306-5354/11/6/532; https://doaj.org/toc/2306-5354; https://doaj.org/article/97cde6c65c99411a85e67574a59b83a6 |
| DOI: | 10.3390/bioengineering11060532 |
| Availability: | https://doi.org/10.3390/bioengineering11060532 https://doaj.org/article/97cde6c65c99411a85e67574a59b83a6 |
| Accession Number: | edsbas.42623DBC |
| Database: | BASE |
| FullText | Text: Availability: 0 CustomLinks: – Url: https://doi.org/10.3390/bioengineering11060532# Name: EDS - BASE (s4221598) Category: fullText Text: View record from BASE – Url: https://www.webofscience.com/api/gateway?GWVersion=2&SrcApp=EBSCO&SrcAuth=EBSCO&DestApp=WOS&ServiceName=TransferToWoS&DestLinkType=GeneralSearchSummary&Func=Links&author=Gazelakis%20E Name: ISI Category: fullText Text: Nájsť tento článok vo Web of Science Icon: https://imagesrvr.epnet.com/ls/20docs.gif MouseOverText: Nájsť tento článok vo Web of Science |
|---|---|
| Header | DbId: edsbas DbLabel: BASE An: edsbas.42623DBC RelevancyScore: 962 AccessLevel: 3 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 962.306396484375 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: Press-Fit Placement of a Rectangular Block Implant in the Resorbed Alveolar Ridge: Surgical and Biomechanical Considerations – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AR" term="%22Efthimios+Gazelakis%22">Efthimios Gazelakis</searchLink><br /><searchLink fieldCode="AR" term="%22Roy+B%2E+Judge%22">Roy B. Judge</searchLink><br /><searchLink fieldCode="AR" term="%22Joseph+E%2E+A%2E+Palamara%22">Joseph E. A. Palamara</searchLink><br /><searchLink fieldCode="AR" term="%22Shiva+Subramanian%22">Shiva Subramanian</searchLink><br /><searchLink fieldCode="AR" term="%22Mohsin+Nazir%22">Mohsin Nazir</searchLink> – Name: TitleSource Label: Source Group: Src Data: Bioengineering, Vol 11, Iss 6, p 532 (2024) – Name: Publisher Label: Publisher Information Group: PubInfo Data: MDPI AG – Name: DatePubCY Label: Publication Year Group: Date Data: 2024 – Name: Subset Label: Collection Group: HoldingsInfo Data: Directory of Open Access Journals: DOAJ Articles – Name: Subject Label: Subject Terms Group: Su Data: <searchLink fieldCode="DE" term="%22rectangular+block+implant%22">rectangular block implant</searchLink><br /><searchLink fieldCode="DE" term="%22rectangular+osteotomy%22">rectangular osteotomy</searchLink><br /><searchLink fieldCode="DE" term="%22primary+retention%22">primary retention</searchLink><br /><searchLink fieldCode="DE" term="%22placement+load%22">placement load</searchLink><br /><searchLink fieldCode="DE" term="%22osseo-integration%22">osseo-integration</searchLink><br /><searchLink fieldCode="DE" term="%22stress+concentration%22">stress concentration</searchLink><br /><searchLink fieldCode="DE" term="%22Technology%22">Technology</searchLink><br /><searchLink fieldCode="DE" term="%22Biology+%28General%29%22">Biology (General)</searchLink><br /><searchLink fieldCode="DE" term="%22QH301-705%2E5%22">QH301-705.5</searchLink> – Name: Abstract Label: Description Group: Ab Data: Rectangular Block Implant (RBIs) were manufactured, using computer-aided-design lathe turning, surface roughened with grit blasting and gamma irradiated. Implants were surgically placed into the resorbed edentulous mandibular ridges of both greyhound dogs (ex vivo and in vivo) and humans; the pooled total was 17 placements. The aim was to achieve mechanical stability and full implant submergence without damage to the mandibular canal and without bone fracture: fulfilment of all of these criteria was deemed to be a successful surgical outcome. Rectangular osteotomy sites were prepared with piezo surgical instrumentation. Sixteen implants were fully submerged and achieved good primary stability without bone fracture and without evidence of impingement of the mandibular canal. One implant placement was deemed a failure due to bone fracture: the event of a random successful outcome was rejected ( p < 0.01 confidence, binomial analysis). Technique of placement yielded excellent mechanical retention: key biomechanical factors that emerged in this process included under preparation of the osteotomy site with the use of specifically designed trial-fit gauges, the viscoelastic property of the peri-implant bone, the flat faces and cornered edges of the block surfaces which enhance stress distribution and mechanical retention, respectively. It was concluded that the surgical protocol for the RBI placement in the resorbed alveolus is a predictable clinical procedure tailored to its specific, unique biomechanical profile. – Name: TypeDocument Label: Document Type Group: TypDoc Data: article in journal/newspaper – Name: Language Label: Language Group: Lang Data: English – Name: NoteTitleSource Label: Relation Group: SrcInfo Data: https://www.mdpi.com/2306-5354/11/6/532; https://doaj.org/toc/2306-5354; https://doaj.org/article/97cde6c65c99411a85e67574a59b83a6 – Name: DOI Label: DOI Group: ID Data: 10.3390/bioengineering11060532 – Name: URL Label: Availability Group: URL Data: https://doi.org/10.3390/bioengineering11060532<br />https://doaj.org/article/97cde6c65c99411a85e67574a59b83a6 – Name: AN Label: Accession Number Group: ID Data: edsbas.42623DBC |
| PLink | https://erproxy.cvtisr.sk/sfx/access?url=https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=edsbas&AN=edsbas.42623DBC |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.3390/bioengineering11060532 Languages: – Text: English Subjects: – SubjectFull: rectangular block implant Type: general – SubjectFull: rectangular osteotomy Type: general – SubjectFull: primary retention Type: general – SubjectFull: placement load Type: general – SubjectFull: osseo-integration Type: general – SubjectFull: stress concentration Type: general – SubjectFull: Technology Type: general – SubjectFull: Biology (General) Type: general – SubjectFull: QH301-705.5 Type: general Titles: – TitleFull: Press-Fit Placement of a Rectangular Block Implant in the Resorbed Alveolar Ridge: Surgical and Biomechanical Considerations Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Efthimios Gazelakis – PersonEntity: Name: NameFull: Roy B. Judge – PersonEntity: Name: NameFull: Joseph E. A. Palamara – PersonEntity: Name: NameFull: Shiva Subramanian – PersonEntity: Name: NameFull: Mohsin Nazir IsPartOfRelationships: – BibEntity: Dates: – D: 01 M: 01 Type: published Y: 2024 Identifiers: – Type: issn-locals Value: edsbas – Type: issn-locals Value: edsbas.oa Titles: – TitleFull: Bioengineering, Vol 11, Iss 6, p 532 (2024 Type: main |
| ResultId | 1 |
Nájsť tento článok vo Web of Science