Schlagwörter: Improved super-elastic Ti-Ni alloy wire (ISW), functional anterior crossbite, differential multiloop edgewise archwire (MEAW) technique, intermaxillary elastic (IME) strategy, Dentistry, Orthodontics and Orthodontology
Beschreibung: An adult female (35 years old) came for orthodontic consultation with a chief complaint of poor dental alignment with protruded mandible. Clinical findings revealed that Class III malocclusion with functional anterior crossbite. Low Hysteresis Improved Super-elastic TieNi alloy wire (ISW), developed by Tokyo Medical and Dental University with ISW curve applied over upper arch for flaring out the upper anterior tooth. MEAW technique applied on lower arch to correct a negative overjet. Treatment was completed within 41 months and patient was pleased with the improvement of appearance and dental alignment.
Publikationsart: text
Dateibeschreibung: application/pdf
Sprache: unknown
Relation: https://www.tjo.org.tw/tjo/vol35/iss3/5; https://www.tjo.org.tw/context/tjo/article/1341/viewcontent/TJO1341_proof.pdf
DOI: 10.38209/2708-2636.1341
Verfügbarkeit: https://www.tjo.org.tw/tjo/vol35/iss3/5
https://doi.org/10.38209/2708-2636.1341
https://www.tjo.org.tw/context/tjo/article/1341/viewcontent/TJO1341_proof.pdf
Rights: http://creativecommons.org/licenses/by-nc-nd/4.0/
Dokumentencode: edsbas.1ED5F60D
Datenbank: BASE
Beschreibung
Abstract:An adult female (35 years old) came for orthodontic consultation with a chief complaint of poor dental alignment with protruded mandible. Clinical findings revealed that Class III malocclusion with functional anterior crossbite. Low Hysteresis Improved Super-elastic TieNi alloy wire (ISW), developed by Tokyo Medical and Dental University with ISW curve applied over upper arch for flaring out the upper anterior tooth. MEAW technique applied on lower arch to correct a negative overjet. Treatment was completed within 41 months and patient was pleased with the improvement of appearance and dental alignment.