Uncertainty quantification of viscoelastic parameters in arterial hemodynamics with the a-FSI blood flow model

Saved in:
Bibliographic Details
Title: Uncertainty quantification of viscoelastic parameters in arterial hemodynamics with the a-FSI blood flow model
Authors: Bertaglia, Giulia, Caleffi, Valerio, Pareschi, Lorenzo, Valiani, Alessandro
Contributors: Bertaglia, Giulia, Caleffi, Valerio, Pareschi, Lorenzo, Valiani, Alessandro
Publication Year: 2021
Collection: Università degli Studi di Ferrara: CINECA IRIS
Subject Terms: Blood flow models, Fluid-structure interaction, Uncertainty quantification, Stochastic collocation methods, IMEX Runge-Kutta schemes, Finite volume methods
Description: This work aims at identifying and quantifying uncertainties related to elastic and viscoelastic parameters, which characterize the arterial wall behavior, in one-dimensional modeling of the human arterial hemodynamics. The chosen uncertain parameters are modeled as random Gaussian-distributed variables, making stochastic the system of governing equations. The proposed methodology is initially validated on a model equation, presenting a thorough convergence study which confirms the spectral accuracy of the stochastic collocation method and the second-order accuracy of the IMEX finite volume scheme chosen to solve the mathematical model. Then, univariate and multivariate uncertain quantification analyses are applied to the a-FSI blood flow model, concerning baseline and patient-specific single-artery test cases. A different sensitivity is depicted when comparing the variability of flow rate and velocity waveforms to the variability of pressure and area, the latter ones resulting much more sensitive to the parametric uncertainties underlying the mechanical characterization of vessel walls. Simulations performed considering both the simple elastic and the more realistic viscoelastic constitutive law show that the great uncertainty of the viscosity parameter plays a major role in the prediction of pressure waveforms, enlarging the confidence interval of this variable. In-vivo recorded patient-specific pressure data falls within the confidence interval of the output obtained with the proposed methodology and expectations of the computed pressures are comparable to the recorded waveforms.
Document Type: article in journal/newspaper
File Description: STAMPA
Language: English
ISBN: 978-0-02-199912-5
0-02-199912-0
Relation: info:eu-repo/semantics/altIdentifier/wos/WOS:000624309300006; volume:430; firstpage:110102-1; lastpage:110102-20; numberofpages:20; journal:JOURNAL OF COMPUTATIONAL PHYSICS; https://hdl.handle.net/11392/2453353; https://www.sciencedirect.com/science/article/pii/S0021999120308767?dgcid=rss_sd_all; https://arxiv.org/abs/2007.01907
DOI: 10.1016/j.jcp.2020.110102
Availability: https://hdl.handle.net/11392/2453353
https://doi.org/10.1016/j.jcp.2020.110102
https://www.sciencedirect.com/science/article/pii/S0021999120308767?dgcid=rss_sd_all
https://arxiv.org/abs/2007.01907
Rights: info:eu-repo/semantics/openAccess
Accession Number: edsbas.1AF16C01
Database: BASE
Be the first to leave a comment!
You must be logged in first