Développement et application du moniteur de tabagisme passif MoNIC [Development and application of the passive smoking monitor MoNIC]

Uloženo v:
Podrobná bibliografie
Název: Développement et application du moniteur de tabagisme passif MoNIC [Development and application of the passive smoking monitor MoNIC]
Autoři: Khanh Huynh, C., Moix, J.B., Dubuis, A.
Zdroj: Revue medicale suisse, vol. 4, no. 144, pp. 430-433
Informace o vydavateli: 2008.
Rok vydání: 2008
Témata: Equipment and Supplies, Humans, Nicotine/analysis, Saliva/chemistry, Tobacco Smoke Pollution/analysis
Popis: A passive sampling device, called Monitor of NICotine (MoNIC), was constructed and evaluated by the laboratory of the Institute for Work and Health to determine nicotine in Environmental Tobacco Smoke (ETS). To support a large campaign on the subject of passive smoking, the CIPRET Valais gracefully distributed more than 1500 MoNIC badges to the Swiss population in order to measure ETS. Non-stimulated saliva was also collected to determine nicotine/cotinine levels of participating volunteers. The inhaled Cigarette Equivalents (CE) by non-smokers was calculated for non-smokers, based on a reference of 0.2 mg of nicotine per cigarette. Using the detected CE on the badge for non-smokers, and comparing it to the nicotine/cotinine levels in saliva, we could confirm the use of the CE concept for estimating exposure to ETS.
Druh dokumentu: Article
Popis souboru: application/pdf
Jazyk: French
Přístupová URL adresa: https://serval.unil.ch/notice/serval:BIB_7C1C70E5E7B8
http://nbn-resolving.org/urn/resolver.pl?urn=urn:nbn:ch:serval-BIB_7C1C70E5E7B89
https://serval.unil.ch/resource/serval:BIB_7C1C70E5E7B8.P001/REF.pdf
Rights: CC BY NC ND
Přístupové číslo: edsair.od......1900..f831c4da9981ca800714f6d0bb63836a
Databáze: OpenAIRE
Popis
Abstrakt:A passive sampling device, called Monitor of NICotine (MoNIC), was constructed and evaluated by the laboratory of the Institute for Work and Health to determine nicotine in Environmental Tobacco Smoke (ETS). To support a large campaign on the subject of passive smoking, the CIPRET Valais gracefully distributed more than 1500 MoNIC badges to the Swiss population in order to measure ETS. Non-stimulated saliva was also collected to determine nicotine/cotinine levels of participating volunteers. The inhaled Cigarette Equivalents (CE) by non-smokers was calculated for non-smokers, based on a reference of 0.2 mg of nicotine per cigarette. Using the detected CE on the badge for non-smokers, and comparing it to the nicotine/cotinine levels in saliva, we could confirm the use of the CE concept for estimating exposure to ETS.