Energy and exergy analyses of gas turbine set and its components

Uloženo v:
Podrobná bibliografie
Název: Energy and exergy analyses of gas turbine set and its components
Autoři: Prpić-Oršić, Jasna, Mrzljak, Vedran, Poljak, Igor, Baressi Šegota, Sandi
Zdroj: XXXIII International scientific conference Trans & MOTAUTO 2025 - Proceedings. :63-67
Informace o vydavateli: 2025.
Rok vydání: 2025
Témata: gas turbine set, the ambient temperature change, energy analysis, exergy analysis, components
Popis: This paper presents energy and exergy analysis results of whole gas turbine set and all its components. From the energy viewpoint, combustion chamber has the lowest energy loss (21.31 MW) and the highest energy efficiency (97.20%) of all gas turbine set components. Exergy analysis shows totally opposite trend in comparison to the energy analysis. From the exergy viewpoint, turbocompressor and turbine have low exergy destruction (both around 12 MW) and very high exergy efficiencies (92.43% for turbocompressor and 96.12% for turbine) at the base ambient state. Simultaneously, at the base ambient state combustion chamber has an exergy destruction of 159 MW and low exergy efficiency of 73.29% only. The combustion chamber is the most sensitive to the ambient temperature change of all components from the gas turbine set – the ambient temperature change of 10 °C will result with combustion chamber exergy efficiency change of approximately 0.67%. Whole gas turbine set (plant) has an energy efficiency of 34.40% and exergy efficiency of 33.08%.
Druh dokumentu: Conference object
ISSN: 1313-5031
Přístupová URL adresa: https://trans-motauto.com/sbornik/2025.pdf
Přístupové číslo: edsair.dris...01492..57cdeb87ca234e263c23c251f1f9b9f6
Databáze: OpenAIRE
Popis
Abstrakt:This paper presents energy and exergy analysis results of whole gas turbine set and all its components. From the energy viewpoint, combustion chamber has the lowest energy loss (21.31 MW) and the highest energy efficiency (97.20%) of all gas turbine set components. Exergy analysis shows totally opposite trend in comparison to the energy analysis. From the exergy viewpoint, turbocompressor and turbine have low exergy destruction (both around 12 MW) and very high exergy efficiencies (92.43% for turbocompressor and 96.12% for turbine) at the base ambient state. Simultaneously, at the base ambient state combustion chamber has an exergy destruction of 159 MW and low exergy efficiency of 73.29% only. The combustion chamber is the most sensitive to the ambient temperature change of all components from the gas turbine set – the ambient temperature change of 10 °C will result with combustion chamber exergy efficiency change of approximately 0.67%. Whole gas turbine set (plant) has an energy efficiency of 34.40% and exergy efficiency of 33.08%.
ISSN:13135031