Mehanička svojstva ortopedskih čeličnih implantata u simuliranim biološkim uvjetima

Uloženo v:
Podrobná bibliografie
Název: Mehanička svojstva ortopedskih čeličnih implantata u simuliranim biološkim uvjetima
Autoři: Antabak, Anko, Dobrić, Ivan
Zdroj: Liječnički vjesnik : glasilo Hrvatskoga liječničkog zbora. 145(5-6):184-190
Informace o vydavateli: 2023.
Rok vydání: 2023
Témata: proteze i implantati, corrosion, prostheses and implants, biokompatibilni materijali – kemija, nehrđajući čelik – kemija, ispitivanje materijala – metode, stainless steel – chemistry, materials testing – methods, bone plates, korozija, tjelesna tekućina, ortopedske pločice, biocompatible materials – chemistry, body fluids
Popis: Questioning the routine metal implant removal after bone fracture healing has increased. One of the main indications for removal is metal weakening in biological bone healing conditions, in addition to reports about its breakage even prior to bone healing. The aim of this study is to investigate the mechanical properties of osteosynthesis plates made out of standard surgical stainless steel in simulated biological conditions. Implants made out of 316L stainless steel were kept for one year in simulated body fluid (SBF). We analysed 48 plates made out of standard surgical stainless steel that were divided in four groups. One was the control group and the remaining were immersed in solutions with various pH values according to pH changes during bone fracture healing. The immersed plates were tested mechanically through one year, and those in the control group at the beginning of the study. During one year microstructural changes of the immersed plates were examined five times using a scanning electron microscope (SEM), and only once in the control group. There were significant microstructural pitting corrosion changes after six months and after one year in all plates that were in simulated biological conditions, regardless of the group pH value. Static and dynamic mechanical plate loading tests were performed one year after storage in solutions with various pH values. Following the complete mechanical testing no statistically significant changes were found between groups kept in simulated biological conditions for one year and the control group. The study showed no changes in the mechanical properties of the investigated implants regardless of significant microstructural changes as a consequence of pitting corrosion in simulated biological conditions, which precludes the probability of implant weakening and indication for its removal one year after fracture fixation.
Brojna su propitivanja potrebe rutinskog odstranjenja metalnog implantata nakon saniranja prijeloma kosti. Pretežita indikacija za odstranjenje jest slabljenje mehaničkih svojstava i pucanje implantata prije cijeljenja kosti. Cilj ovog istraživanja bio je ispitati mehanička svojstva osteosintetske pločice izrađene od standardnoga kirurškog čelika u simuliranim biološkim uvjetima. U istraživanju smo koristili implantate nehrđajućeg čelika 316L i pohranili ih kroz godinu dana u simuliranome biološkom mediju (engl. SBF – simulated body fluid). Analizirano je 48 pločica standardnoga kirurškog čelika podijeljeno u četiri skupine. Jedna je kontrolna. Ostale su bile uronjene u otopine različitih pH vrijednosti. Uronjene pločice testirane su nakon godinu dana, a kontrolna odmah na početku istraživanja. Tijekom godinu dana analizirala se promjena mikrostrukture uronjenih pločica skenirajući elektronskim mikroskopom (SEM) u pet navrata, a kontrolna grupa samo jednom. Na pločicama koje su bile u biološkim simuliranim uvjetima, bez obzira na pH medija, značajno je veći broj jamičastih korozija kod mjerenja nakon šest mjeseci i godinu dana. Nakon godinu dana pohrane u medijima različite pH mjerene su vrijednosti mehaničkog, statičkog i dinamičkog opterećenja pločica. Niti jedno načinjeno mehaničko testiranje nije pokazalo statistički značajnu razliku između kontrolne skupine pločica i onih koje su bile u biološki simuliranim uvjetima kroz godinu dana. Nepromijenjena mehanička svojstava istraživanih implantata, unatoč značajnim promjenama mikrostrukture nastale kao posljedica jamičaste korozije u biološki simuliranim uvjetima, otklanjaju vjerojatnost slabljenja pločice kao i indikaciju za njezino odstranjenje u tom vremenskom razdoblju.
Druh dokumentu: Article
ISSN: 0024-3477
DOI: 10.26800/lv-145-5-6-2
Přístupová URL adresa: https://hrcak.srce.hr/307070
Přístupové číslo: edsair.dris...01492..376833a6f39b88b1be29f65d52022d38
Databáze: OpenAIRE
FullText Text:
  Availability: 0
CustomLinks:
  – Url: https://explore.openaire.eu/search/publication?articleId=dris___01492%3A%3A376833a6f39b88b1be29f65d52022d38
    Name: EDS - OpenAIRE (s4221598)
    Category: fullText
    Text: View record at OpenAIRE
  – Url: https://www.webofscience.com/api/gateway?GWVersion=2&SrcApp=EBSCO&SrcAuth=EBSCO&DestApp=WOS&ServiceName=TransferToWoS&DestLinkType=GeneralSearchSummary&Func=Links&author=Antabak%20A
    Name: ISI
    Category: fullText
    Text: Nájsť tento článok vo Web of Science
    Icon: https://imagesrvr.epnet.com/ls/20docs.gif
    MouseOverText: Nájsť tento článok vo Web of Science
Header DbId: edsair
DbLabel: OpenAIRE
An: edsair.dris...01492..376833a6f39b88b1be29f65d52022d38
RelevancyScore: 934
AccessLevel: 3
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 933.779541015625
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Mehanička svojstva ortopedskih čeličnih implantata u simuliranim biološkim uvjetima
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Antabak%2C+Anko%22">Antabak, Anko</searchLink><br /><searchLink fieldCode="AR" term="%22Dobrić%2C+Ivan%22">Dobrić, Ivan</searchLink>
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <i>Liječnički vjesnik : glasilo Hrvatskoga liječničkog zbora</i>. 145(5-6):184-190
– Name: Publisher
  Label: Publisher Information
  Group: PubInfo
  Data: 2023.
– Name: DatePubCY
  Label: Publication Year
  Group: Date
  Data: 2023
– Name: Subject
  Label: Subject Terms
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22proteze+i+implantati%22">proteze i implantati</searchLink><br /><searchLink fieldCode="DE" term="%22corrosion%22">corrosion</searchLink><br /><searchLink fieldCode="DE" term="%22prostheses+and+implants%22">prostheses and implants</searchLink><br /><searchLink fieldCode="DE" term="%22biokompatibilni+materijali+–+kemija%22">biokompatibilni materijali – kemija</searchLink><br /><searchLink fieldCode="DE" term="%22nehrđajući+čelik+–+kemija%22">nehrđajući čelik – kemija</searchLink><br /><searchLink fieldCode="DE" term="%22ispitivanje+materijala+–+metode%22">ispitivanje materijala – metode</searchLink><br /><searchLink fieldCode="DE" term="%22stainless+steel+–+chemistry%22">stainless steel – chemistry</searchLink><br /><searchLink fieldCode="DE" term="%22materials+testing+–+methods%22">materials testing – methods</searchLink><br /><searchLink fieldCode="DE" term="%22bone+plates%22">bone plates</searchLink><br /><searchLink fieldCode="DE" term="%22korozija%22">korozija</searchLink><br /><searchLink fieldCode="DE" term="%22tjelesna+tekućina%22">tjelesna tekućina</searchLink><br /><searchLink fieldCode="DE" term="%22ortopedske+pločice%22">ortopedske pločice</searchLink><br /><searchLink fieldCode="DE" term="%22biocompatible+materials+–+chemistry%22">biocompatible materials – chemistry</searchLink><br /><searchLink fieldCode="DE" term="%22body+fluids%22">body fluids</searchLink>
– Name: Abstract
  Label: Description
  Group: Ab
  Data: Questioning the routine metal implant removal after bone fracture healing has increased. One of the main indications for removal is metal weakening in biological bone healing conditions, in addition to reports about its breakage even prior to bone healing. The aim of this study is to investigate the mechanical properties of osteosynthesis plates made out of standard surgical stainless steel in simulated biological conditions. Implants made out of 316L stainless steel were kept for one year in simulated body fluid (SBF). We analysed 48 plates made out of standard surgical stainless steel that were divided in four groups. One was the control group and the remaining were immersed in solutions with various pH values according to pH changes during bone fracture healing. The immersed plates were tested mechanically through one year, and those in the control group at the beginning of the study. During one year microstructural changes of the immersed plates were examined five times using a scanning electron microscope (SEM), and only once in the control group. There were significant microstructural pitting corrosion changes after six months and after one year in all plates that were in simulated biological conditions, regardless of the group pH value. Static and dynamic mechanical plate loading tests were performed one year after storage in solutions with various pH values. Following the complete mechanical testing no statistically significant changes were found between groups kept in simulated biological conditions for one year and the control group. The study showed no changes in the mechanical properties of the investigated implants regardless of significant microstructural changes as a consequence of pitting corrosion in simulated biological conditions, which precludes the probability of implant weakening and indication for its removal one year after fracture fixation.<br />Brojna su propitivanja potrebe rutinskog odstranjenja metalnog implantata nakon saniranja prijeloma kosti. Pretežita indikacija za odstranjenje jest slabljenje mehaničkih svojstava i pucanje implantata prije cijeljenja kosti. Cilj ovog istraživanja bio je ispitati mehanička svojstva osteosintetske pločice izrađene od standardnoga kirurškog čelika u simuliranim biološkim uvjetima. U istraživanju smo koristili implantate nehrđajućeg čelika 316L i pohranili ih kroz godinu dana u simuliranome biološkom mediju (engl. SBF – simulated body fluid). Analizirano je 48 pločica standardnoga kirurškog čelika podijeljeno u četiri skupine. Jedna je kontrolna. Ostale su bile uronjene u otopine različitih pH vrijednosti. Uronjene pločice testirane su nakon godinu dana, a kontrolna odmah na početku istraživanja. Tijekom godinu dana analizirala se promjena mikrostrukture uronjenih pločica skenirajući elektronskim mikroskopom (SEM) u pet navrata, a kontrolna grupa samo jednom. Na pločicama koje su bile u biološkim simuliranim uvjetima, bez obzira na pH medija, značajno je veći broj jamičastih korozija kod mjerenja nakon šest mjeseci i godinu dana. Nakon godinu dana pohrane u medijima različite pH mjerene su vrijednosti mehaničkog, statičkog i dinamičkog opterećenja pločica. Niti jedno načinjeno mehaničko testiranje nije pokazalo statistički značajnu razliku između kontrolne skupine pločica i onih koje su bile u biološki simuliranim uvjetima kroz godinu dana. Nepromijenjena mehanička svojstava istraživanih implantata, unatoč značajnim promjenama mikrostrukture nastale kao posljedica jamičaste korozije u biološki simuliranim uvjetima, otklanjaju vjerojatnost slabljenja pločice kao i indikaciju za njezino odstranjenje u tom vremenskom razdoblju.
– Name: TypeDocument
  Label: Document Type
  Group: TypDoc
  Data: Article
– Name: ISSN
  Label: ISSN
  Group: ISSN
  Data: 0024-3477
– Name: DOI
  Label: DOI
  Group: ID
  Data: 10.26800/lv-145-5-6-2
– Name: URL
  Label: Access URL
  Group: URL
  Data: <link linkTarget="URL" linkTerm="https://hrcak.srce.hr/307070" linkWindow="_blank">https://hrcak.srce.hr/307070</link>
– Name: AN
  Label: Accession Number
  Group: ID
  Data: edsair.dris...01492..376833a6f39b88b1be29f65d52022d38
PLink https://erproxy.cvtisr.sk/sfx/access?url=https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=edsair&AN=edsair.dris...01492..376833a6f39b88b1be29f65d52022d38
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.26800/lv-145-5-6-2
    Languages:
      – Text: Undetermined
    PhysicalDescription:
      Pagination:
        PageCount: 7
        StartPage: 184
    Subjects:
      – SubjectFull: proteze i implantati
        Type: general
      – SubjectFull: corrosion
        Type: general
      – SubjectFull: prostheses and implants
        Type: general
      – SubjectFull: biokompatibilni materijali – kemija
        Type: general
      – SubjectFull: nehrđajući čelik – kemija
        Type: general
      – SubjectFull: ispitivanje materijala – metode
        Type: general
      – SubjectFull: stainless steel – chemistry
        Type: general
      – SubjectFull: materials testing – methods
        Type: general
      – SubjectFull: bone plates
        Type: general
      – SubjectFull: korozija
        Type: general
      – SubjectFull: tjelesna tekućina
        Type: general
      – SubjectFull: ortopedske pločice
        Type: general
      – SubjectFull: biocompatible materials – chemistry
        Type: general
      – SubjectFull: body fluids
        Type: general
    Titles:
      – TitleFull: Mehanička svojstva ortopedskih čeličnih implantata u simuliranim biološkim uvjetima
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Antabak, Anko
      – PersonEntity:
          Name:
            NameFull: Dobrić, Ivan
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 01
              Type: published
              Y: 2023
          Identifiers:
            – Type: issn-print
              Value: 00243477
            – Type: issn-locals
              Value: edsair
            – Type: issn-locals
              Value: edsairFT
          Numbering:
            – Type: volume
              Value: 145
            – Type: issue
              Value: 5-6
          Titles:
            – TitleFull: Liječnički vjesnik : glasilo Hrvatskoga liječničkog zbora
              Type: main
ResultId 1