Mehanička svojstva ortopedskih čeličnih implantata u simuliranim biološkim uvjetima
Uložené v:
| Názov: | Mehanička svojstva ortopedskih čeličnih implantata u simuliranim biološkim uvjetima |
|---|---|
| Autori: | Antabak, Anko, Dobrić, Ivan |
| Zdroj: | Liječnički vjesnik : glasilo Hrvatskoga liječničkog zbora. 145(5-6):184-190 |
| Informácie o vydavateľovi: | 2023. |
| Rok vydania: | 2023 |
| Predmety: | proteze i implantati, corrosion, prostheses and implants, biokompatibilni materijali – kemija, nehrđajući čelik – kemija, ispitivanje materijala – metode, stainless steel – chemistry, materials testing – methods, bone plates, korozija, tjelesna tekućina, ortopedske pločice, biocompatible materials – chemistry, body fluids |
| Popis: | Questioning the routine metal implant removal after bone fracture healing has increased. One of the main indications for removal is metal weakening in biological bone healing conditions, in addition to reports about its breakage even prior to bone healing. The aim of this study is to investigate the mechanical properties of osteosynthesis plates made out of standard surgical stainless steel in simulated biological conditions. Implants made out of 316L stainless steel were kept for one year in simulated body fluid (SBF). We analysed 48 plates made out of standard surgical stainless steel that were divided in four groups. One was the control group and the remaining were immersed in solutions with various pH values according to pH changes during bone fracture healing. The immersed plates were tested mechanically through one year, and those in the control group at the beginning of the study. During one year microstructural changes of the immersed plates were examined five times using a scanning electron microscope (SEM), and only once in the control group. There were significant microstructural pitting corrosion changes after six months and after one year in all plates that were in simulated biological conditions, regardless of the group pH value. Static and dynamic mechanical plate loading tests were performed one year after storage in solutions with various pH values. Following the complete mechanical testing no statistically significant changes were found between groups kept in simulated biological conditions for one year and the control group. The study showed no changes in the mechanical properties of the investigated implants regardless of significant microstructural changes as a consequence of pitting corrosion in simulated biological conditions, which precludes the probability of implant weakening and indication for its removal one year after fracture fixation. Brojna su propitivanja potrebe rutinskog odstranjenja metalnog implantata nakon saniranja prijeloma kosti. Pretežita indikacija za odstranjenje jest slabljenje mehaničkih svojstava i pucanje implantata prije cijeljenja kosti. Cilj ovog istraživanja bio je ispitati mehanička svojstva osteosintetske pločice izrađene od standardnoga kirurškog čelika u simuliranim biološkim uvjetima. U istraživanju smo koristili implantate nehrđajućeg čelika 316L i pohranili ih kroz godinu dana u simuliranome biološkom mediju (engl. SBF – simulated body fluid). Analizirano je 48 pločica standardnoga kirurškog čelika podijeljeno u četiri skupine. Jedna je kontrolna. Ostale su bile uronjene u otopine različitih pH vrijednosti. Uronjene pločice testirane su nakon godinu dana, a kontrolna odmah na početku istraživanja. Tijekom godinu dana analizirala se promjena mikrostrukture uronjenih pločica skenirajući elektronskim mikroskopom (SEM) u pet navrata, a kontrolna grupa samo jednom. Na pločicama koje su bile u biološkim simuliranim uvjetima, bez obzira na pH medija, značajno je veći broj jamičastih korozija kod mjerenja nakon šest mjeseci i godinu dana. Nakon godinu dana pohrane u medijima različite pH mjerene su vrijednosti mehaničkog, statičkog i dinamičkog opterećenja pločica. Niti jedno načinjeno mehaničko testiranje nije pokazalo statistički značajnu razliku između kontrolne skupine pločica i onih koje su bile u biološki simuliranim uvjetima kroz godinu dana. Nepromijenjena mehanička svojstava istraživanih implantata, unatoč značajnim promjenama mikrostrukture nastale kao posljedica jamičaste korozije u biološki simuliranim uvjetima, otklanjaju vjerojatnost slabljenja pločice kao i indikaciju za njezino odstranjenje u tom vremenskom razdoblju. |
| Druh dokumentu: | Article |
| ISSN: | 0024-3477 |
| DOI: | 10.26800/lv-145-5-6-2 |
| Prístupová URL adresa: | https://hrcak.srce.hr/307070 |
| Prístupové číslo: | edsair.dris...01492..376833a6f39b88b1be29f65d52022d38 |
| Databáza: | OpenAIRE |
| FullText | Text: Availability: 0 CustomLinks: – Url: https://explore.openaire.eu/search/publication?articleId=dris___01492%3A%3A376833a6f39b88b1be29f65d52022d38 Name: EDS - OpenAIRE (s4221598) Category: fullText Text: View record at OpenAIRE – Url: https://www.webofscience.com/api/gateway?GWVersion=2&SrcApp=EBSCO&SrcAuth=EBSCO&DestApp=WOS&ServiceName=TransferToWoS&DestLinkType=GeneralSearchSummary&Func=Links&author=Antabak%20A Name: ISI Category: fullText Text: Nájsť tento článok vo Web of Science Icon: https://imagesrvr.epnet.com/ls/20docs.gif MouseOverText: Nájsť tento článok vo Web of Science |
|---|---|
| Header | DbId: edsair DbLabel: OpenAIRE An: edsair.dris...01492..376833a6f39b88b1be29f65d52022d38 RelevancyScore: 934 AccessLevel: 3 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 933.779541015625 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: Mehanička svojstva ortopedskih čeličnih implantata u simuliranim biološkim uvjetima – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AR" term="%22Antabak%2C+Anko%22">Antabak, Anko</searchLink><br /><searchLink fieldCode="AR" term="%22Dobrić%2C+Ivan%22">Dobrić, Ivan</searchLink> – Name: TitleSource Label: Source Group: Src Data: <i>Liječnički vjesnik : glasilo Hrvatskoga liječničkog zbora</i>. 145(5-6):184-190 – Name: Publisher Label: Publisher Information Group: PubInfo Data: 2023. – Name: DatePubCY Label: Publication Year Group: Date Data: 2023 – Name: Subject Label: Subject Terms Group: Su Data: <searchLink fieldCode="DE" term="%22proteze+i+implantati%22">proteze i implantati</searchLink><br /><searchLink fieldCode="DE" term="%22corrosion%22">corrosion</searchLink><br /><searchLink fieldCode="DE" term="%22prostheses+and+implants%22">prostheses and implants</searchLink><br /><searchLink fieldCode="DE" term="%22biokompatibilni+materijali+–+kemija%22">biokompatibilni materijali – kemija</searchLink><br /><searchLink fieldCode="DE" term="%22nehrđajući+čelik+–+kemija%22">nehrđajući čelik – kemija</searchLink><br /><searchLink fieldCode="DE" term="%22ispitivanje+materijala+–+metode%22">ispitivanje materijala – metode</searchLink><br /><searchLink fieldCode="DE" term="%22stainless+steel+–+chemistry%22">stainless steel – chemistry</searchLink><br /><searchLink fieldCode="DE" term="%22materials+testing+–+methods%22">materials testing – methods</searchLink><br /><searchLink fieldCode="DE" term="%22bone+plates%22">bone plates</searchLink><br /><searchLink fieldCode="DE" term="%22korozija%22">korozija</searchLink><br /><searchLink fieldCode="DE" term="%22tjelesna+tekućina%22">tjelesna tekućina</searchLink><br /><searchLink fieldCode="DE" term="%22ortopedske+pločice%22">ortopedske pločice</searchLink><br /><searchLink fieldCode="DE" term="%22biocompatible+materials+–+chemistry%22">biocompatible materials – chemistry</searchLink><br /><searchLink fieldCode="DE" term="%22body+fluids%22">body fluids</searchLink> – Name: Abstract Label: Description Group: Ab Data: Questioning the routine metal implant removal after bone fracture healing has increased. One of the main indications for removal is metal weakening in biological bone healing conditions, in addition to reports about its breakage even prior to bone healing. The aim of this study is to investigate the mechanical properties of osteosynthesis plates made out of standard surgical stainless steel in simulated biological conditions. Implants made out of 316L stainless steel were kept for one year in simulated body fluid (SBF). We analysed 48 plates made out of standard surgical stainless steel that were divided in four groups. One was the control group and the remaining were immersed in solutions with various pH values according to pH changes during bone fracture healing. The immersed plates were tested mechanically through one year, and those in the control group at the beginning of the study. During one year microstructural changes of the immersed plates were examined five times using a scanning electron microscope (SEM), and only once in the control group. There were significant microstructural pitting corrosion changes after six months and after one year in all plates that were in simulated biological conditions, regardless of the group pH value. Static and dynamic mechanical plate loading tests were performed one year after storage in solutions with various pH values. Following the complete mechanical testing no statistically significant changes were found between groups kept in simulated biological conditions for one year and the control group. The study showed no changes in the mechanical properties of the investigated implants regardless of significant microstructural changes as a consequence of pitting corrosion in simulated biological conditions, which precludes the probability of implant weakening and indication for its removal one year after fracture fixation.<br />Brojna su propitivanja potrebe rutinskog odstranjenja metalnog implantata nakon saniranja prijeloma kosti. Pretežita indikacija za odstranjenje jest slabljenje mehaničkih svojstava i pucanje implantata prije cijeljenja kosti. Cilj ovog istraživanja bio je ispitati mehanička svojstva osteosintetske pločice izrađene od standardnoga kirurškog čelika u simuliranim biološkim uvjetima. U istraživanju smo koristili implantate nehrđajućeg čelika 316L i pohranili ih kroz godinu dana u simuliranome biološkom mediju (engl. SBF – simulated body fluid). Analizirano je 48 pločica standardnoga kirurškog čelika podijeljeno u četiri skupine. Jedna je kontrolna. Ostale su bile uronjene u otopine različitih pH vrijednosti. Uronjene pločice testirane su nakon godinu dana, a kontrolna odmah na početku istraživanja. Tijekom godinu dana analizirala se promjena mikrostrukture uronjenih pločica skenirajući elektronskim mikroskopom (SEM) u pet navrata, a kontrolna grupa samo jednom. Na pločicama koje su bile u biološkim simuliranim uvjetima, bez obzira na pH medija, značajno je veći broj jamičastih korozija kod mjerenja nakon šest mjeseci i godinu dana. Nakon godinu dana pohrane u medijima različite pH mjerene su vrijednosti mehaničkog, statičkog i dinamičkog opterećenja pločica. Niti jedno načinjeno mehaničko testiranje nije pokazalo statistički značajnu razliku između kontrolne skupine pločica i onih koje su bile u biološki simuliranim uvjetima kroz godinu dana. Nepromijenjena mehanička svojstava istraživanih implantata, unatoč značajnim promjenama mikrostrukture nastale kao posljedica jamičaste korozije u biološki simuliranim uvjetima, otklanjaju vjerojatnost slabljenja pločice kao i indikaciju za njezino odstranjenje u tom vremenskom razdoblju. – Name: TypeDocument Label: Document Type Group: TypDoc Data: Article – Name: ISSN Label: ISSN Group: ISSN Data: 0024-3477 – Name: DOI Label: DOI Group: ID Data: 10.26800/lv-145-5-6-2 – Name: URL Label: Access URL Group: URL Data: <link linkTarget="URL" linkTerm="https://hrcak.srce.hr/307070" linkWindow="_blank">https://hrcak.srce.hr/307070</link> – Name: AN Label: Accession Number Group: ID Data: edsair.dris...01492..376833a6f39b88b1be29f65d52022d38 |
| PLink | https://erproxy.cvtisr.sk/sfx/access?url=https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=edsair&AN=edsair.dris...01492..376833a6f39b88b1be29f65d52022d38 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.26800/lv-145-5-6-2 Languages: – Text: Undetermined PhysicalDescription: Pagination: PageCount: 7 StartPage: 184 Subjects: – SubjectFull: proteze i implantati Type: general – SubjectFull: corrosion Type: general – SubjectFull: prostheses and implants Type: general – SubjectFull: biokompatibilni materijali – kemija Type: general – SubjectFull: nehrđajući čelik – kemija Type: general – SubjectFull: ispitivanje materijala – metode Type: general – SubjectFull: stainless steel – chemistry Type: general – SubjectFull: materials testing – methods Type: general – SubjectFull: bone plates Type: general – SubjectFull: korozija Type: general – SubjectFull: tjelesna tekućina Type: general – SubjectFull: ortopedske pločice Type: general – SubjectFull: biocompatible materials – chemistry Type: general – SubjectFull: body fluids Type: general Titles: – TitleFull: Mehanička svojstva ortopedskih čeličnih implantata u simuliranim biološkim uvjetima Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Antabak, Anko – PersonEntity: Name: NameFull: Dobrić, Ivan IsPartOfRelationships: – BibEntity: Dates: – D: 01 M: 01 Type: published Y: 2023 Identifiers: – Type: issn-print Value: 00243477 – Type: issn-locals Value: edsair – Type: issn-locals Value: edsairFT Numbering: – Type: volume Value: 145 – Type: issue Value: 5-6 Titles: – TitleFull: Liječnički vjesnik : glasilo Hrvatskoga liječničkog zbora Type: main |
| ResultId | 1 |
Nájsť tento článok vo Web of Science