Validation of the investigator argus y-28 qs kit on the seqstudio™ genetic analyzer for hid: a new panel file for genemapper id-x software v1.6.

Uloženo v:
Podrobná bibliografie
Název: Validation of the investigator argus y-28 qs kit on the seqstudio™ genetic analyzer for hid: a new panel file for genemapper id-x software v1.6.
Autoři: Soldati, Giulia, Turrina, Stefania, Ausania, Francesco
Zdroj: International Journal of Legal Medicine; Nov2025, Vol. 139 Issue 6, p2635-2645, 11p
Témata: MICROSATELLITE repeats, DNA fingerprinting, FORENSIC genetics, GENETIC software, STATISTICAL accuracy, RESEARCH evaluation, SENSITIVITY & specificity (Statistics)
Abstrakt: Background: The Investigator Argus Y-28 QS Kit is a 27-locus, six-dye multiplex, which includes six rapidly mutating Short Tandem Repeats (RM Y-STRs). Methods: A new text file containing the optimized panel and bin sets for GeneMapper ID-X Software v1.6 has been prepared. In addition, an internal validation study was conducted on the Investigator Argus Y-28 QS kit using the SeqStudio™ Genetic Analyzer for HID. Results: The full results of that study are presented here, including data on precision, sensitivity, reproducibility, stutter determination, and reduction volume analysis. A concordance study and three case reports are documented. Finally, the kit was successfully used to conduct a proficiency test. Conclusions: The obtained findings achieved a satisfactory performance of the Investigator Argus Y-28 QS Kit on the SeqStudio™ Genetic Analyzer for HID. [ABSTRACT FROM AUTHOR]
Copyright of International Journal of Legal Medicine is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Databáze: Complementary Index
Popis
Abstrakt:Background: The Investigator Argus Y-28 QS Kit is a 27-locus, six-dye multiplex, which includes six rapidly mutating Short Tandem Repeats (RM Y-STRs). Methods: A new text file containing the optimized panel and bin sets for GeneMapper ID-X Software v1.6 has been prepared. In addition, an internal validation study was conducted on the Investigator Argus Y-28 QS kit using the SeqStudio™ Genetic Analyzer for HID. Results: The full results of that study are presented here, including data on precision, sensitivity, reproducibility, stutter determination, and reduction volume analysis. A concordance study and three case reports are documented. Finally, the kit was successfully used to conduct a proficiency test. Conclusions: The obtained findings achieved a satisfactory performance of the Investigator Argus Y-28 QS Kit on the SeqStudio™ Genetic Analyzer for HID. [ABSTRACT FROM AUTHOR]
ISSN:09379827
DOI:10.1007/s00414-025-03539-6