Novel oxygen optode sensor with fast response time: an in-depth characterization and assessment of the HydroFlash O2, applicable for several ocean observing platforms.

Gespeichert in:
Bibliographische Detailangaben
Titel: Novel oxygen optode sensor with fast response time: an in-depth characterization and assessment of the HydroFlash O2, applicable for several ocean observing platforms.
Autoren: Hahn, Tobias, Körtzinger, Arne
Quelle: Frontiers in Marine Science; 2025, p1-23, 23p
Schlagwörter: OXYGEN detectors, CLIMATE change, DETECTORS, THERMAL properties, OCEANOGRAPHIC research stations, CALIBRATION
Abstract: Optics-based sensors, called optodes, for oxygen are used for routine operations on autonomous instrumentation and profiling platforms with great success. Observations of oxygen gradients with high spatial and temporal resolution become increasingly important, while shortcomings still exist, namely, time constant problems, stability issues, or accuracy levels, that limit leveraging their full scientific and operational potential. Here, we demonstrate the utility of a novel, although currently not commercially available optode, the HydroFlash O2. It was manufactured by Kongsberg Maritime Contros GmbH between 2014 and 2019, and peer-reviewed studies illustrate its use until today. Our work comprises its first integrated characterization with data from 13 HydroFlash O2 optodes assessing oxygen, temperature, salinity and hydrostatic pressure dependence, long-term stability and drift, response time, and air-calibration compatibility. We multi-point calibrated this optode up to a root mean square error (RMSE) of <1 µ mol L-1 (mean RMSE: 1.79 ± 0.50 µ mol L-1), depending on the fit model type. Our laboratory setup yielded a temperature-dependent response time of τ 63% = 3.31 ± 0.58 s, showing no significant difference between a weakly turbulent and turbulent flow, and was at least 50 % faster compared to the two most common optodes in oceanography, i.e., 4330 (Aanderaa) and SBE 63 (Sea-Bird Scientific). We assessed its pressure dependence between 0–5797 dbar, yielding an overall factor of 2.372 ± 0.409 % per 1,000 dbar based on three multi-point calibrated, drift-corrected optodes and five CTD (conductivity - temperature - depth) profiles. Ship-underway, mooring, and CTD-cast applications promise high-quality observations, including fast oxygen level changes. The optode revealed a strong sensitivity of the sensor spot, causing erroneous oxygen measurements when exposed to direct solar irradiation during an Argo float test profile. The drift assessment covering a maximum time span of approximately 3 years is based on two optodes and yielded linear (R2 = 0.98) and exponential (τ = 2.35 ± 0.30 yr, 95 % CI) drift behaviors. The HydroFlash O2 is applicable in low to high oxygen, pressure, and temperature conditions, yet we do not call for additional performance studies unless the manufacturer reactivates its production and reduces sensor spot issues. In an ocean affected by climate change, reliable oxygen optodes will contribute crucial information about the global oxygen and carbon budget, e.g., through observations in the mixed layer, thermocline, or deep sea, and require assessments of existing and promising instrumentation. [ABSTRACT FROM AUTHOR]
Copyright of Frontiers in Marine Science is the property of Frontiers Media S.A. and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Datenbank: Complementary Index