Evaluating BOLD functional MRI biophysical simulation approaches: impact of vascular geometry, magnetic field calculations, and water diffusion models.
Uloženo v:
| Název: | Evaluating BOLD functional MRI biophysical simulation approaches: impact of vascular geometry, magnetic field calculations, and water diffusion models. |
|---|---|
| Autoři: | Berman AJL; Department of Physics, Carleton University, Ottawa, ON, Canada.; University of Ottawa Institute of Mental Health Research at The Royal, Ottawa, ON, Canada., Chaussé J; Rotman Research Institute, Baycrest Health Sciences, North York, ON, Canada.; Department of Chemistry, University of Waterloo, Waterloo, ON, Canada., Hartung G; Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, MA, United States.; Department of Radiology, Harvard Medical School, Boston, MA, United States.; Institute for Mechanics, Computational Mechanics Group, Technical University of Darmstadt, Darmstadt, Germany., Polimeni JR; Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, MA, United States.; Department of Radiology, Harvard Medical School, Boston, MA, United States.; Harvard-MIT Program in Health Sciences and Technology, Massachusetts Institute of Technology, Cambridge, MA, United States., Chen JJ; Rotman Research Institute, Baycrest Health Sciences, North York, ON, Canada.; Department of Medical Biophysics, University of Toronto, Toronto, ON, Canada. |
| Zdroj: | BioRxiv : the preprint server for biology [bioRxiv] 2025 Sep 04. Date of Electronic Publication: 2025 Sep 04. |
| Způsob vydávání: | Journal Article; Preprint |
| Jazyk: | English |
| Informace o časopise: | Country of Publication: United States NLM ID: 101680187 Publication Model: Electronic Cited Medium: Internet ISSN: 2692-8205 (Electronic) Linking ISSN: 26928205 NLM ISO Abbreviation: bioRxiv Subsets: PubMed not MEDLINE |
| Abstrakt: | Biophysical simulations have guided the development of blood oxygenation level-dependent (BOLD) functional MRI (fMRI) acquisitions and signal models that relate the BOLD signal to the underlying physiology, such as calibrated BOLD and vascular fingerprinting. Numerous simulation techniques have been developed, however, few of them have been directly compared, thus limiting the assessment of the accuracy and interchangeability of these methods as well as the accuracy of the quantitative techniques derived from them. In this work, we compared the accuracy and computational demands of eight previously published simulation approaches that adopt different geometries (ranging from infinite cylinders to synthetic vascular anatomical networks (VANs)), field offset calculations (analytical and Fourier-based), and water diffusion implementations (Monte Carlo and convolution-based), all of which are available in an open-source Python toolkit, BOLDsωimsuite . The reference simulation approach for comparison used three-dimensional infinite cylinders, analytical field offsets, and Monte Carlo diffusion. When compared with the reference approach, most of the simulations, including two- and three-dimensional geometries, were in excellent agreement when assuming the intravascular signal contribution was small. Two commonly employed simulation approaches were notably biased; both used two-dimensional geometries with overly simplified vasculature or field offset calculations. In general, the simulated intravascular signal was the least consistent across approaches, thus potentially resulting in larger errors when the intravascular signal contribution is large. Lastly, the VAN results were in good agreement with the reference but they diverged slightly, yet systematically, from each other at smaller radii INLINEMATH , primarily driven by intravascular signal differences. We conclude, therefore, that the reference approach is an attractive option for exploratory simulations in the many cases where anatomical and hemodynamic realism is not needed, balancing ease of implementation, accessibility, versatility, computational efficiency, accuracy of results, and interpretability. These findings help pave the way for a broader adoption of forward modelling of the BOLD signal and more reliable interpretations of biophysical simulations aiming to develop quantitative models of the BOLD signal. |
| Competing Interests: | 10 Declaration of Competing Interests |
| Grant Information: | R01 EB032746 United States EB NIBIB NIH HHS; U19 NS123717 United States NS NINDS NIH HHS; R01 MH111419 United States MH NIMH NIH HHS; R01 NS128843 United States NS NINDS NIH HHS; R01 MH111438 United States MH NIMH NIH HHS; P41 EB030006 United States EB NIBIB NIH HHS; F32 MH125599 United States MH NIMH NIH HHS |
| Contributed Indexing: | Keywords: BOLD fMRI; Monte Carlo simulations; biophysical modelling; quantitative MRI; simulation; vascular fingerprinting |
| Entry Date(s): | Date Created: 20250915 Date Completed: 20250922 Latest Revision: 20250922 |
| Update Code: | 20250922 |
| PubMed Central ID: | PMC12424777 |
| DOI: | 10.1101/2025.08.29.673098 |
| PMID: | 40950239 |
| Databáze: | MEDLINE |
Buďte první, kdo okomentuje tento záznam!
Full Text Finder
Nájsť tento článok vo Web of Science